Hotwire ATM Line Cards
Models 8335, 8355, 8365, and 8385
User’s Guide
Document No. 8335-A2-GB20-70
About This Guide
Document Purpose and Intended Audience
New Features for This Document Release
Document Summary
Section
Description
v
Section
Description
www.paradyne.com
Product-Related Documents
www.paradyne.com
Document Number Document Title
vi
About the Hotwire ATM Line Cards
1
Hotwire ATM Line Cards
1-1
Hotwire ATM Line Card Features
Asynchronous Terminal Interface (ATI).
Alarm indication.
Diagnostics.
Device and test monitoring.
Software upgrade.
DSL Features
High speeds and multiple line codes:
High density:
1-2
ATM Features
Classes of service.
Auto configuration.
Multiple virtual circuits.
ATM statistics.
Endpoint Support Features
Third-party endpoint support.
www.paradyne.com
Model 6390 Modem support.
Automatic rate adaptation.
1-3
Network Configurations
PSTN Voice
Traffic
Customer Premises
LAN
Hotwire ATM
Line Card
Voice
Gateway
ISP
SCM
Integrated
Access
Device
(IAD)
ATM Cells
ATM Cells
ATM
Network
DSL
Corporate
Site
GranDSLAM
00-16682
Figure 1-1. Endpoint with Voice Interfaces
Hotwire ATM
Line Card
Customer Premises
LAN
ISP
SCM
ATM Cells
ATM
Network
ATM Cells
DSL
Router
Corporate
Site
GranDSLAM
00-16681-01
Figure 1-2. Router Endpoint
1-4
SNMP Management Capabilities
Management Information Base (MIB) Support
www.paradyne.com
SNMP Trap Support
1-5
Menus and Screens
2
Menu and Screen Formats
1
2
3
Menu Title
Menu List
Letter Navigation Keys
A
A
2-1
Components of a Hotwire Screen
1
2
3
4
System Header Line
<no name>
Display Area
Input Line
f
a
2-2
Status Line
Slot 02: 8335: Card Status: _ _ _ Wan Status: U
Slot 02: 8335: D D D D D D D D D D D D D D D D
Slot 02: 8335: Press ? For Help
Line 1 Text
Description
Naming Conventions for Ports and Interfaces
Port Name
Interface Name
2-3
General Navigation Keys
Table 2-1. General Navigation Keys
Keys
Definition
Pop-Up Menu Navigation Keys
Table 2-2. Pop-Up Menu Navigation Keys
Keys Definition
2-4
User Login Screen (MCP)
NOTE:
2-5
Quick Card Select Screen
Procedure
A
Goto:
2-6
Table 2-3. Quick Card Select Screen
Column
Heading Display
Description
SCM, SDSL(16)
Reach(24) ADSL(12), SHDSL(24)
2-7
Exiting from the System
Manually Logging Out
Procedure
Automatically Logging Out
2-8
Configuration
3
Overview
Saving and Restoring Configuration Options
3-1
Entering Card Information
A-A-A
3-2
Procedure
For . . .
Enter . . .
3-3
Entering the Time and Date
A-A-B
Setting Spectrum Management (Models 8355 and 8385)
A-A-G
A-A-G
A-B-B
NOTE:
A-B-B
3-4
Procedure
For . . .
Enter . . .
Annex A
Annex B
Enable
Disable
3-6
For . . .
Enter . . .
USA
UK
Other Functions of the Card Menu
3-7
Configuring the DSL Ports
A-B-B
DSL Port Configuration – Model 8335
3-8
Procedure
Edit
Reset
dsl1
dsl16
NOTE:
3-9
For . . .
Enter . . .
Standard
Nx128
Fixed
Auto Baud
144, 272, 400, 528, 784, 1168,
144, 256, 384, 512, 768, 1024,
1552, 2320 kbps
1536 kbps
144, 272, 400, 528, 784, 1168,
144, 256, 384, 512, 768, 1024,
1552, 2320 kbps
1536 kbps
0
15
15
0
0
900
Enable
Disable
3-10
DSL Port Configuration – Model 8355
Edit/Reset Model 8355 DSL Ports
Procedure
Edit
Reset
Copy
dsl1
dsl24
3-11
For . . .
Enter . . .
A-A-G
8.5 – 14.5 kft
>14.5 kft
A-A-G
Short
Medium
Long
A-A-G
Same
Segregated<=3km
Segregated>3km
0 – 74 volts
D
A-A-G
+12dB – -14dB
3-12
For . . .
Enter . . .
A-A-G
32 2176 kbps
32 2176 kbps
32 2176 kbps
32 1632 kbps
32 1440 kbps
32 1088 kbps
32 kbps – 2176 kbps
3-13
For . . .
Enter . . .
0
900,
D
0
0
2176 kbps
D
D
2176 kbps
Enable
Disable
Enable
Disable
Copy Model 8355 DSL Port Configurations
Procedure
Copy
dsl1
dsl24
Copy From
dsl1
dsl24
yes
Copy To
Save Changes?
3-15
DSL Port Configuration – Model 8365
Procedure
Edit
Reset
dsl1
dsl12
For . . .
Enter . . .
Multimode
DMT
G.Lite
ANSI
3-16
For . . .
Enter . . .
Fast
Interleaved
Adaptive
Fixed
32–8000 kbps
64–3008 kbps
32–832 kbps
32–512 kbps
32–8000 kbps
64–3008 kbps
32–8000 kbps
64–3008 kbps
32–832 kbps
64–512 kbps
32–832 kbps
32–512 kbps
0–31 dB
3-17
For . . .
Enter . . .
0–31 dB
0–31 dB
0
0
0
900,
900,
900,
D
D
D
0
0
900,
900,
D
D
3-18
For . . .
Enter . . .
Enable
Disable
DSL Port Configuration – Model 8385
Procedure
Edit
Reset
dsl1
dsl24
3-19
NOTE:
A-A-G
Allowed Speeds
For . . .
Enter . . .
Asymmetric
Symmetric
A-A-G
A-A-G
NOTE:
3-20
For . . .
Enter . . .
A-A-G
Short
Medium
Long
A-A-G
Adaptive
Fixed
2 – 15 dB
0
900,
D
3-21
For . . .
Enter . . .
0
0
0
0
900,
900,
900,
900,
D
D
D
D
0
0
0
15
127
900,
D
3-22
For . . .
Enter . . .
Enable
Disable
Enable
Disable
3-23
Configuring the ATM Physical Layer (Models 8335, 8365, and 8385)
A-B-C
3-24
Procedure
dsl1:1
dsl16:1
dsl1:1
dsl1:1
dsl12:1
dsl24:1
For . . .
Enter . . .
Enable
Disable
Enable
Disable
3-25
Configuring ATM Parameters
A-E-A
3-26
Procedure
dsl1:1
dsl12:1
dsl16:1
dsl1:1
dsl1:1
dsl24:1
For . . .
Enter . . .
0
9999
0
0
1000,
D
D
1000,
3-27
Configuring ATM Cross Connections
A-E-B
3-28
Procedure
dsl1:1
dsl12:1
dsl16:1
dsl1:1
dsl1:1
dsl24:1
u
d
For . . .
Enter . . .
15
0
32 255
AUTOBAUD
PACKET
IP MGT
VOICE.
Enable
Disable
Delete
Up
Down
3-30
For . . .
Enter . . .
Enable
Disable
01–18
S
01–03
C
01–16
01–24
01–12
3-31
Configuring ATM Traffic Profiles
A-E-C
3-32
Table 3-1. Traffic Profile Characteristics
Profile
Name
Class
PD
POL
PCR
CDVT
SCR
MBS
AUTOBAUD
IP MGT
PACKET:
3-33
VOICE
Table 3-2. Conversion Guidelines
For Standard Speeds
For Nx128k Speeds
Kilobits per Equals cells per
Kilobits per
second . . .
Equals cells per
second . . .
second . . . second . . .
3-34
Procedure
u
d
For . . .
Enter . . .
CBR
rt-VBR
nrt-VBR
UBR
Yes
No
N
T
D
1
3-35
For . . .
Enter . . .
1
156000
1
1
3-36
Clearing Cross Connections
A-E-D
Procedure
dsl1:1
dsl12:1
dsl16:1
dsl1:1
dsl1:1
dsl24:1
3-37
Configuring Rate Shaping (Models 8335, 8365, 8385)
A-E-E
Procedure
dsl1:1
dsl24:1
512
46080
d
3-38
Entering Service Node Configuration Information
(Models 8335, 8365, and 8385)
A-F-A
3-39
Procedure
dsl1:1
dsl12:1
dsl16:1
dsl1:1
dsl1:1
dsl24:1
For . . .
Enter . . .
NOTES:
3-41
Entering Service Node Management Configuration Information
(Models 8335 and 8385)
A-F-B
3-42
Procedure
u
d
For . . .
Enter . . .
dsl1:1
dsl16:1
dsl1:1
dsl24:1
0
15
32 255
3-43
Monitoring
4
What to Monitor
4-1
Viewing Card Status and Information
Procedure
B-A
4-2
Table 4-1. Monitoring – Card Options
Card Info Screen
B-A-A
Card Name
Card Contact
Card Location
Card Up Time
Type
Model Number
Serial Number
Firmware Revision
Hardware Revision
Line Code Revision
PLD Revision
Specific PLD Revision
Time/Date Screen
B-A-B
4-3
Viewing Physical Ports Status
Procedure
B-B
4-4
Table 4-2. Monitoring – Physical Ports (1 of 6)
Active List Screen
B-B-A
Num
Name
Status
ATM Physical Layer Screen Models 8335, 8365, and 8385 Only
B-B-C
ATM Segment Endpoint
Payload Scrambler
4-5
Table 4-2. Monitoring – Physical Ports (2 of 6)
DSL Link Performance Summary Screen – Model 8335
B-B-D
Operating Speed
Down Margin
Down Attenuation
Up Margin
Up Attenuation
Current Link Up Time
Card Up Time
Link Down Count
Current Interval Counter
DSL Link Performance Summary Screen – Model 8355
B-B-D
CPE Vendor ID
ATU-R/ATU-C Margin
ATU-R/ATU-C Attenuation
ATU-R/ATU-C Transmit Power
Current Link Up Time
Card Up Time
ATU-R/ATU-C Current Tx Speeds
ATU-R/ATU-C Previous Tx Speeds
ATU-R/ATU-C Attainable Speeds
ATU-R/ATU-C Relative Capacity
4-6
Table 4-2. Monitoring – Physical Ports (3 of 6)
DSL Link Performance Summary Screen – Model 8365
B-B-D
CPE Vendor ID
Latency
Line Code
Card Up Time
Percent Link Up
Operating Speeds
Down Margin
Down Attenuation
Up Margin
Up Attenuation
Current Link Up Time
Attainable Speeds
Relative Capacity
4-7
Table 4-2. Monitoring – Physical Ports (4 of 6)
DSL Link Performance Summary Screen – Model 8385
B-B-D
CPE Vendor ID
Down Margin
Down Attenuation
Up Margin
Up Attenuation
Operating Speed
Attainable Speed
Current Link Up Time
Card Up Time
Relative Capacity
Number of Repeaters in Loop
4-8
Table 4-2. Monitoring – Physical Ports (5 of 6)
DSL Error Stats Screen – Model 8355
B-B-F
ATU-R/ATU-C ES
ATU-R/ATU-C SES
ATU-R/ATU-C UAS
ATU-R/ATU-C LOFS
ATU-C LOSS
ATU-R Loss of Power Seconds
Current Interval Counter
4-9
Table 4-2. Monitoring – Physical Ports (6 of 6)
DSL Error Stats Screen – Model 8365
B-B-F
dn err secs, up err secs
dn svr err sec, up svr err secs
dn unavail sec, up unavail sec
Link Down Count
SN loss of power
Current Interval Counter
DSL Error Stats Screen – Model 8385
B-B-F
dn err secs, up err secs
dn svr err sec, up svr err secs
dn unavail sec, up unavail sec
dn CRC Anomalies, up CRC Anomalies
dn LOSW sec, up LOSW sec
Link Down Count
Current Interval Counter
4-10
Monitoring ATM Activity
Procedure
B-E
Table 4-3. Monitoring – ATM Switch (1 of 7)
ATM Parameters Screen Models 8335, 8365, and 8385
B-E-A
rt-VBR and nrt-VBR CAC Percent Bandwidth Utilization
Uncorrected HEC Count
OCD Event Count
ATM Parameters Screen Model 8355
Uncorrected HEC Count
B-E-A
4-11
Table 4-3. Monitoring – ATM Switch (2 of 7)
ATM Cross Connect Screen Models 8335 and 8385
B-E-B
VPI
VCI
Profile Name
Status
Up
Down
CSN
Total Connections for this Interface
Available Connections
ATM Cross Connect Screen Model 8355
B-E-B
VPI
VCI
Tx Profile
Rx Profile
Status
Up
Down
Seg Endpt
CSN
Total Connections For This Interface
Available Connections
4-12
Table 4-3. Monitoring – ATM Switch (3 of 7)
ATM Cross Connect Screen – Model 8365
B-E-B
VPI
VCI
Dnstream Profile
Upstream Profile
Status
Up
Down
CSN
Total Connections For This Interface
Available Connections
4-13
Table 4-3. Monitoring – ATM Switch (4 of 7)
ATM Traffic Profiles Screen – Models 8335, 8365, and 8385
B-E-C
Profile Name
Class
CBR
rt-VBR
nrt-VBR
UBR
PD
POL
N
T
D
PCR
CDVT
SCR
MBS
Total Profiles
4-14
Table 4-3. Monitoring – ATM Switch (5 of 7)
ATM Traffic Profiles Screen – Model 8355
B-E-C
Profile Name
Class
UBR
PD
Total Profiles
4-15
Table 4-3. Monitoring – ATM Switch (6 of 7)
ATM Aggregate Statistics Screen
B-E-D
Interface Name
Total Cells Received
Total Rx Cells Dropped
Total Cells Sent
Total TX Cells Dropped
Corrected HEC
Uncorrected HEC
OCD Events
Unknown Cells
VCC Performance Statistics Screen
B-E-E
Interface Name
VPI
VCI
Class
Total Cells Received
Total Rx Cells Dropped
Total Cells Sent
Total TX Cells Dropped
Corrected HEC
Uncorrected HEC
OCD Events
Unknown Cells
4-16
Table 4-3. Monitoring – ATM Switch (7 of 7)
Unknown Cell Log Screen
B-E-F
Action
Interface Name
VPI
VCI
Time
ATM Connection Status Screen
B-E-G
Interface Name
VPI
0
15
VCI
32 255
Current Interval Counter
4-17
Monitoring SN Information
Procedure
B-F
4-18
Table 4-4. Monitoring – SN Information
SN Information Screen
B-F-A
N/A
Interface Name
Name
Contact
Location
Circuit ID
Model Number
Serial Number
Firmware Rev
Vendor ID
ITU Standard Rev
Service Node Management Screen (Models 8335 and 8385 Only
B-F-B
Interface
IP Address
Subnet Mask
VPI
VCI
4-19
Front Panel LEDs
Type
LED
LED is . . . *
Indicating . . .
ALT BANK
ALT BANK
ALT BANK
ALT BANK
9-16
9-16
13-24
1-12
13-24
1-12
1-8
1-8
ATM
ATM
SDSL
SDSL
ATM
SHDSL
ATM
ReachDSL
G.DMT
G.Lite
8335
8335
8385
8355
8365
00-16661
00-16661
01-16986
02-17210
00-16719
4-20
Diagnostics
5
Overview
5-1
Self-Test
Procedure
D-A
5-2
Table 5-1. Monitoring – Selftest
Selftest Screen
D-A
5-3
Table 5-2. Monitoring – Card Alarms (1 of 6)
Card Alarms Screen – Model 8335
D-B
Major Alarms
Selftest
ATM Bus Failure
DSL Port Selftest Fail
Minor Alarms
Config Error
Loss of Cell Delineation
Loss of Signal
CAC Exceeded
5-5
Table 5-2. Monitoring – Card Alarms (2 of 6)
Card Alarms Screen – Model 8355
D-B
Major Alarms
Selftest
DSL Port Selftest Failure
Initialization Failure
ATM Bus Failure
5-6
Table 5-2. Monitoring – Card Alarms (3 of 6)
Card Alarms Screen – Model 8355 (Continued)
D-B
Minor Alarms
Config Error
Loss of Cell Delineation
Loss of Signal
Loss of Power
Loss of Frame
Loss of Signal Quality
Error Seconds Threshold
Severely Errored Seconds Threshold
Unavailable Seconds Threshold
Increasing Rate Threshold
Decreasing Rate Threshold
5-7
Table 5-2. Monitoring – Card Alarms (4 of 6)
Card Alarms Screen – Model 8365
D-B
Major Alarms
Selftest
ATM Bus Failure
DSL Port Selftest Fail
Minor Alarms
Config Error
Loss of Cell Delineation
Loss of Signal
Error Seconds
Severely Errored Seconds
Unavailable Seconds
SN Loss of Power
5-8
Table 5-2. Monitoring – Card Alarms (5 of 6)
Card Alarms Screen – Model 8385
D-B
Major Alarms
Selftest
ATM Bus Failure
DSL Port Selftest Failure
5-9
Table 5-2. Monitoring – Card Alarms (6 of 6)
Card Alarms Screen – Model 8385 (Continued)
D-B
Minor Alarms
Config Error
Loss of Cell Delineation
Loss of Signal
Error Seconds
Severely Errored Seconds
Unavailable Seconds
Loss of Sync Word Second
CRC Anomalies Threshold
SNR Margin Threshold
Attenuation Threshold
Repeater Segment Down
SN Loss of Power
CAC Exceeded
5-10
Procedure
Table 5-3. Diagnostics – ATM Ping
ATM Ping Screen
D-C-A
Interface name
VPI
VCI
Type
End2End
Segment
Direction
Status
Class
Source
Elapsed Time
Cells Sent
Cells Received
Round Trip Delay:
Min
Max
Avg
5-12
ATM Ping Summary
Procedure
D-C-B
5-13
Table 5-4. Diagnostics – ATM Ping Summary
ATM Ping Summary Screen
D-C-B
DSL Intf
VPI
VCI
Type
Dir
Elapsed Time
Cells Sent
Cells Recvd
RTT Delay:
Min
Max
Avg
Source
5-14
Loopback Test (Model 8385 Only)
Procedure
D-F
5-15
Start
Stop
Figure 5-1. SHDSL Data Path
5-16
Table 5-5. Diagnostics – Loopback Test
Loopback Test Screen – Model 8385
D-F
Port Name
Unit ID
Serial No.
Unit Side
Duration
Test
Total Tests Active
No of Repeaters in Loop
5-17
Maintenance Procedures
6
Overview
6-1
Uploading and Downloading a Configuration
A-A-D
6-3
Uploading a Configuration
Procedure
/paradyne/83xx/chicago.cfg
M1
Downloading a Configuration
Procedure
/paradyne/83xx/chicago.cfg
M1
Configuration Loader Statistics
Packets Sent
Packets Received
Bytes Sent
Bytes Received
Transfer Status
6-4
Resetting the Card
A-A-E
6-5
Completed successfully
A-A-F-B
6-8
Menus
A
Configuration Menu
A-1
Applications Menu
Diagnostics Menu
A-3
SNMP Traps
B
Trap Managers
SNMP Traps
Table B-1. SNMP Traps (1 of 6)
Event
Description
Variable Bindings
B-1
Table B-1. SNMP Traps (2 of 6)
Event
Description
Variable Bindings
B-2
Table B-1. SNMP Traps (3 of 6)
Event
Description
Variable Bindings
B-3
Table B-1. SNMP Traps (4 of 6)
Event
Description
Variable Bindings
B-4
Table B-1. SNMP Traps (5 of 6)
Event
Description
Variable Bindings
B-5
Table B-1. SNMP Traps (6 of 6)
Event
Description
Variable Bindings
B-6
Connector Pin Assignments
C
Model 8820 GranDSLAM Telco Connector Pinouts
Pin
Number 50
Pin
Number 1
00-16714
Port
Pins
Port
Pins
Port
Pins
Port
Pins
Port
Pins
C-1
Model 8620 GranDSLAM Telco Connector Pinouts
50
26
25
97-15323
1
CONN #
for Slots 1–3
CONN PINS
(Tip, Ring)
CONN #
for Slots 1–3
CONN PINS
(Tip, Ring)
C-2
Technical Specifications
D
Table D-1. ATM Line Card Technical Specifications (1 of 2)
Specifications
Criteria*
Size
Weight
Approvals
Safety Certifications
Power
Physical
Environment
D-1
Table D-1. ATM Line Card Technical Specifications (2 of 2)
Specifications
Criteria*
Line Code
DSL Line Rates
D-2
|